Karcher HDS 13-20-4 S EU Manuale Utente Pagina 24

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 23
– 3
Please follow the national rules and regu-
lations for fuel spray jets of the respective
country.
Please follow the national rules and regu-
lations for accident prevention of the re-
spective country. Fuel spray jets must be
tested regularly and the results of these
tests must be documented in writing.
The heating appliance of the machine is
an ignition plant. All national laws and
regulations about heating systems must
also be followed.
As per the applicable national guidelines,
the first time this high-pressure cleaner
must be taken into operation by a skilled
person. KÄRCHER has already per-
formed this initial start-up for you and has
documented it accordingly. The docu-
mentation can be requested at your
KÄRCHER partner. Please have the part
and plant number of the appliance availa-
ble when enquiring about the documenta-
tion.
We would like to point out that the appli-
ance must be repeatedly checked by a
skilled person as prescribed by the appli-
cable national regulations. Please con-
tact your KÄRCHER partner.
Safety devices serve for the protection of the
user and must not be put out of operation or
by passed with respect to their function.
While reducing the water supply at the
pump head or with the Servopress - reg-
ulation the overflow valve opens and part
of the water flows back to the pump suck
side.
If the hand-spray gun is closed, so that
the whole water flows back to the pump
suck side, the pressure switch at the
overflow valve shuts down the pump.
If the hand spray gun is opened, the pres-
sure switch on the cylinder head turns the
pump back on.
The overflow valve is set by the manufac-
turer and sealed. Setting only by customer
service.
The safety valve opens, when the over-
flow valve resp. the pressure switch is
broken.
The safety valve is set by the manufacturer
and sealed. Setting only by customer service.
The water shortage safeguard prevents
the burner to be turned on when there is
water shortage.
A sieve prevents the contamination of
the safeguard and must be cleaned reg-
ulary.
The temperature stop switches off the
machine when the waste gases have
reached very high temperatures.
Warning
Risk of injury! Device, tubes, high pressure
hose and connections must be in faultless
condition. Otherwise, the appliance must
not be used.
Î Lock parking brake.
Figure 3
Caution
Hook the electric supply line into the cable
guide of the right handle bow. Ensure that
the cable is not damaged.
Note: Push the bottle in securely to pene-
trate the closure. Do not remove bottle until
it is empty.
Note: To protect the device, the burner is
switched off 5 hours after the system care
bottle is empty.
The system care prevents the calcifica-
tion of the heating spiral while operating
with calciferous tap water. It is dosed
into the supply in the float container
drop by drop.
Safety instructions
Safety Devices
Overflow valve with two pressure
switches
Safety valve
Water shortage safeguard
Temperature stop for exhaust gases
Start up
Installing the handle
Replace the system care bottle
24 EN